Agreement between a fitness test and polar s810 for estimating maximum oxygen uptake

"Objective Identifying agreement between data for estimating maximum oxygen uptake obtained by a fitness test and the Polar S810 heart rate monitor. Methods This was an observational agreement study comparing two methods for estimating VO2max (simultaneously and independently). Two protocols we...

Descripción completa

Detalles Bibliográficos
Autores Principales: Cortés-Reyes E., Echeverry-Raad J., Mancera-Soto E.M., Ramos Caballero D.M.
Formato: Artículo (Article)
Lenguaje:Inglés (English)
Publicado: Universidad Nacional de Colombia 2009
Materias:
Acceso en línea:https://repository.urosario.edu.co/handle/10336/23145
id ir-10336-23145
recordtype dspace
spelling ir-10336-231452021-01-21T08:26:15Z Agreement between a fitness test and polar s810 for estimating maximum oxygen uptake Concordancia en la estimación del consumo máximo de oxígeno entre una prueba de esfuerzo y el polar s810® Cortés-Reyes E. Echeverry-Raad J. Mancera-Soto E.M. Ramos Caballero D.M. Exercise Fitness test Heart rate Oxygen consumption "Objective Identifying agreement between data for estimating maximum oxygen uptake obtained by a fitness test and the Polar S810 heart rate monitor. Methods This was an observational agreement study comparing two methods for estimating VO2max (simultaneously and independently). Two protocols were applied to 46 athletes from the Universidad Nacional de Colombia who had been trained in endurance sports (one at rest and maximum effort i). Results Lin's concordance correlation coefficient CCC) was 0.31 (p and lt;0.003). This coefficient did not change substantially when stratified by gender (male: CCC 0.29; 0.04-0.54 95%CI; female CCC 0.15; 0.14-0.45 95%CI), type of sport (group: CCC 0.38; 0.04-0.54 95%CI; individual: CCC 0.16; 0.20-0.52 95%CI) and its value only improved in athletes aged 24.1 to 28 (CCC 0.65; 0.35-0.93 95%CI). Regarding the maximum test, the Polar S810 gave higher or lower values, with 42 mL/kg/min cut-off. Conclusions Agreement between both methods was generally poor and in the different subgroups of athletes; this meant that the results obtained from estimating VO2max could not be exchanged between the fitness and Polar S810 tests." 2009 2020-05-26T00:00:00Z info:eu-repo/semantics/article info:eu-repo/semantics/publishedVersion 1240064 https://repository.urosario.edu.co/handle/10336/23145 eng info:eu-repo/semantics/openAccess application/pdf Universidad Nacional de Colombia instname:Universidad del Rosario reponame:Repositorio Institucional EdocUR
institution EdocUR - Universidad del Rosario
collection DSpace
language Inglés (English)
topic Exercise
Fitness test
Heart rate
Oxygen consumption
spellingShingle Exercise
Fitness test
Heart rate
Oxygen consumption
Cortés-Reyes E.
Echeverry-Raad J.
Mancera-Soto E.M.
Ramos Caballero D.M.
Agreement between a fitness test and polar s810 for estimating maximum oxygen uptake
description "Objective Identifying agreement between data for estimating maximum oxygen uptake obtained by a fitness test and the Polar S810 heart rate monitor. Methods This was an observational agreement study comparing two methods for estimating VO2max (simultaneously and independently). Two protocols were applied to 46 athletes from the Universidad Nacional de Colombia who had been trained in endurance sports (one at rest and maximum effort i). Results Lin's concordance correlation coefficient CCC) was 0.31 (p and lt;0.003). This coefficient did not change substantially when stratified by gender (male: CCC 0.29; 0.04-0.54 95%CI; female CCC 0.15; 0.14-0.45 95%CI), type of sport (group: CCC 0.38; 0.04-0.54 95%CI; individual: CCC 0.16; 0.20-0.52 95%CI) and its value only improved in athletes aged 24.1 to 28 (CCC 0.65; 0.35-0.93 95%CI). Regarding the maximum test, the Polar S810 gave higher or lower values, with 42 mL/kg/min cut-off. Conclusions Agreement between both methods was generally poor and in the different subgroups of athletes; this meant that the results obtained from estimating VO2max could not be exchanged between the fitness and Polar S810 tests."
format Artículo (Article)
author Cortés-Reyes E.
Echeverry-Raad J.
Mancera-Soto E.M.
Ramos Caballero D.M.
author_facet Cortés-Reyes E.
Echeverry-Raad J.
Mancera-Soto E.M.
Ramos Caballero D.M.
author_sort Cortés-Reyes E.
title Agreement between a fitness test and polar s810 for estimating maximum oxygen uptake
title_short Agreement between a fitness test and polar s810 for estimating maximum oxygen uptake
title_full Agreement between a fitness test and polar s810 for estimating maximum oxygen uptake
title_fullStr Agreement between a fitness test and polar s810 for estimating maximum oxygen uptake
title_full_unstemmed Agreement between a fitness test and polar s810 for estimating maximum oxygen uptake
title_sort agreement between a fitness test and polar s810 for estimating maximum oxygen uptake
publisher Universidad Nacional de Colombia
publishDate 2009
url https://repository.urosario.edu.co/handle/10336/23145
_version_ 1690577328603660288
score 11,828437